Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Ultrasonography ; : 75-82, 2021.
Article in English | WPRIM | ID: wpr-919501

ABSTRACT

Radiofrequency ablation (RFA) is a thermal ablation technique widely used for the management of benign thyroid nodules. To date, five academic societies in various countries have reported clinical practice guidelines, opinion statements, or recommendations regarding the use of thyroid RFA. However, despite some similarities, there are also differences among the guidelines, and a consensus is required regarding safe and effective treatment in Asian countries. Therefore, a task force was organized by the guideline committee of the Asian Conference on Tumor Ablation with the goal of devising recommendations for the clinical use of thyroid RFA. The recommendations in this article are based on a comprehensive analysis of the current literature and the consensus opinion of the task force members.

2.
Ultrasonography ; : 191-220, 2020.
Article | WPRIM | ID: wpr-835332

ABSTRACT

The first edition of the guidelines for the use of ultrasound contrast agents was published in 2004, dealing with liver applications. The second edition of the guidelines in 2008 reflected changes in the available contrast agents and updated the guidelines for the liver, as well as implementing some nonliver applications. The third edition of the contrast-enhanced ultrasound (CEUS) guidelines was the joint World Federation for Ultrasound in Medicine and Biology-European Federation of Societies for Ultrasound in Medicine and Biology (WFUMB-EFSUMB) venture in conjunction with other regional US societies such as Asian Federation of Societies for Ultrasound in Medicine and Biology, resulting in a simultaneous duplicate on liver CEUS in the official journals of both WFUMB and EFSUMB in 2013. However, no guidelines were described mainly for Sonazoid due to limited clinical experience only in Japan and Korea. The new proposed consensus statements and recommendations provide general advice on the use of Sonazoid and are intended to create standard protocols for the use and administration of Sonazoid in hepatic and pancreatobiliary applications in Asian patients and to improve patient management.

3.
Chinese Medical Journal ; (24): 68-71, 2013.
Article in English | WPRIM | ID: wpr-331320

ABSTRACT

<p><b>BACKGROUND</b>Early detection with screening mammography can potentially reduce breast cancer mortality rates. To achieve an efficient screening, a peer review system provides a compensatory double-check reviewing, will hopefully to prevent the omission of detectable lesions and reduce unnecessary recall.</p><p><b>METHODS</b>In 2009, 4643 initial mammographic screenings reported by 74 screening radiologists had negative results with a recall rate of less than 5%. In the same year, 2538 initial positives screened by 18 screening radiologists had a recall rate higher than 15%. Those 7181 randomized screenings were evenly distributed for reassessment by 39 reviewing radiologists. The disagreement of assessments between the reviewers and screening radiologists was recorded. The differential rate was defined as the number of the disagreements divided by the number of audited films reviewed by a screening radiologist. The equality of the differential rates for each screening radiologists with negative and positive assessments was compared by a Chi-square test. The performance of the 39 auditors was measured by the Kendall's tau statistic. P values less than 0.05 were considered statistically significant.</p><p><b>RESULTS</b>The mean differential rate for screening radiologists of negative assessments was 6.7% (P = 0.588), while 35.0% for positive assessments were significant (P < 0.001). The result indicated that most of the initial negative assessments reported by the screening radiologists were generally accepted by the reviewers but not the positive assessments. With respect to the 39 reviewers, there was no significant evidence for the association of the difference rates between negative and positive assessments. Nine reviewers were found to have their differential rate for negative and positive assessments larger than the average of the population. Eleven reviewers were found to have their differential rates smaller than the average for both. Thirteen reviewers had their differential rates smaller than the average for negative assessments but larger than the average for positive assessments. The opposite condition was found for six reviewers. The Kendall's tau statistic was 0.038 (P = 0.735).</p><p><b>CONCLUSIONS</b>Reviewers usually agreed with the opinion of the initial screening doctors who reported negative findings. Therefore, a 5% recall rate as the lower range of reviewing negatives may be still too high. The recall rate of more than 15% was significantly related to improper interpretation, especially when the differential rate is 25% or higher, a warning to the underperforming screening radiologist is recommended. An ideal reviewer should interpret films independently. Reviewers with tendencies to be followers or contrarians should not be enrolled in the reviewing system.</p>


Subject(s)
Female , Humans , Breast Neoplasms , Diagnostic Imaging , Early Detection of Cancer , Mammography , Peer Review , Reproducibility of Results , Taiwan
4.
Chinese Medical Journal ; (24): 767-770, 2007.
Article in English | WPRIM | ID: wpr-240333

ABSTRACT

<p><b>BACKGROUND</b>Bone age development is one of the significant indicators depicting the growth status of children. However, bone age assessment is an heuristic and tedious work for pediatricians. We developed a computerized bone age estimation system based on the analysis of geometric features of carpal bones.</p><p><b>METHODS</b>The geometric features of carpals were extracted and analyzed to judge the bone age of children by computerized shape and area description. Four classifiers, linear, nearest neighbor, back-propagation neural network, and radial basis function neural network, were adopted to categorize bone age. Principal component and discriminate analyses were employed to improve assorting accuracy.</p><p><b>RESULTS</b>The hand X-ray films of 465 boys and 444 girls served as our database. The features were extracted from carpal bone images, including shape, area, and sequence. The proposed normalization area ratio method was effective in bone age classification by simulation. Besides, features statistics showed similar results between the standard of the Greulich and Pyle atlas and our database.</p><p><b>CONCLUSIONS</b>The bone area has a higher discriminating power to judge bone age. The ossification sequence of trapezium and trapezoid bones between Taiwanese and the atlas of the GP method is quite different. These results also indicate that carpal bone assessment with classification of neural networks can be correct and practical.</p>


Subject(s)
Child , Child, Preschool , Female , Humans , Infant , Male , Age Determination by Skeleton , Carpal Bones , Neural Networks, Computer
5.
Korean Journal of Radiology ; : 28-34, 2006.
Article in English | WPRIM | ID: wpr-192505

ABSTRACT

OBJECTIVE: We wanted to assess the usefulness of four-dimensional (4D) ultrasonography (US), i.e., real-time three-dimensional US, as an adjunct for performing various US-guided interventional procedures in superficial lesions. MATERIALS AND METHODS: Thirty-three patients were referred for US-guided interventional procedures for superficial lesions, including core biopsy in 19, fine-needle aspiration in eight, therapeutic drug injection in four and needle puncture in two. The procedures were performed under 4D US guidance. We reviewed the pathologic/cytologic results of the core biopsies or needle aspirations, and also the outcomes of drug injection or needle puncture. RESULTS: For all the patients who underwent 4D US-guided core biopsy, the specimens were adequate for making the pathological diagnosis, and specimens were successfully obtained for those patients who underwent 4D US-guided aspiration. The patients treated with 4D US-guided therapeutic drug injection or needle puncture had a good response. No major procedure-related complications occurred. The procedural times were similar to those procedural times with using two-dimensional US. CONCLUSION: Combining the two dimensional and 4D US techniques aids the physician when performing US-guided interventional procedures for the superficial lesions.


Subject(s)
Middle Aged , Male , Humans , Female , Aged, 80 and over , Aged , Adult , Adolescent , Ultrasonography, Interventional/methods , Punctures/methods , Neoplasms/pathology , Injections/methods , Imaging, Three-Dimensional
SELECTION OF CITATIONS
SEARCH DETAIL